Hi,
Tamer Fares wrote:
> i made for label file (full) p1^p2-p3+p4=p5 only
> i made the mono label file too
>
>
> i recorded 60 utterance raw file
>
> i run the demo
>
> the same error appeared to me
>
> system is PLAIN
> ERROR [+2121] HInit : Too Few Observation Sequences [0]
> HInit -A -C trn.cnf D -T 1 -S train.scp -m 1 -u tmvw -w 3 -H init.mmf
> ...... -l aa -o aa state-5_mcp-75_lf0-3.prt
It means that there is no "aa" in the training data.
> this was happened also when i worked on 50 utterance i added 20
> additional and the same error appear to me for the phoneme aa
> can this error belong to something else that it is a few training data
> for the phoneme aa
> (can be for example that i included for full label format the
> p1^p2-p3+p4=p5 only
Please check whether your labes files contain any "aa" or not.
Of course phone boundaries should be assigned.
Regards,
Heiga ZEN (Byung Ha CHUN)
--
------------------------------------------------
Heiga ZEN (in Japanese pronunciation)
Byung Ha CHUN (in Korean pronunciation)
Department of Computer Science and Engineering
Nagoya Institute of Technology
Gokiso-cho, Showa-ku, Nagoya 466-8555 Japan
http://www.sp.nitech.ac.jp/~zen
------------------------------------------------