[hts-users:01209] Re: how to set the hlist.conf


Thanks zen.And now I have another questions.
1 .  I gained the data as follow:

------ Source: /hts/HTS-demo_CMU-ARCTIC-SLT2/data/cmp/cmu_us_arctic_slt_a0001.cmp ------
  Sample Bytes:  312      Sample Kind:   USER
  Num Comps:     78       Sample Period: 5000.0 us
  Num Samples:   669      File Format:   HTK
------------------------------------ Samples: 0->-1 ------------------------------------
0:       2.467   1.391   0.333   0.366   0.175   0.146   0.086   0.140  -0.089   0.144
         0.055   0.018   0.016   0.027  -0.028   0.055  -0.006   0.025   0.011  -0.024
        -0.044   0.054  -0.024   0.008  -0.037   1.191   0.601   0.212   0.256   0.102
         0.127   0.063   0.118  -0.029   0.119   0.024   0.058  -0.003   0.064   0.003
         0.033   0.020   0.011   0.032   0.006  -0.024   0.042   0.007   0.010   0.017
        -2.552  -1.580  -0.241  -0.220  -0.146  -0.039  -0.047  -0.045   0.119  -0.048
        -0.063   0.080  -0.037   0.075   0.061  -0.044   0.051  -0.029   0.042   0.060
         0.039  -0.022   0.063   0.003   0.107-10000000000.000-10000000000.000-10000000000.000
......

I am sorry to tell you that I cann't understand the data in the cmu_us_arctic_slt_a0001.cmp file.Could you help me and interpret them . Dose it means the first window MGC MERGE with the first window f0 ?

2. I am  a  novice  in Speech Recognition , and the  HTS is difficulty for me(you know that there is no HTSbook ...) .How can  I  improve  my  understanding with  the HTS.
Looking forward to you reply.

Thanks again,

2008-03-09,"Heiga ZEN (Byung Ha CHUN)" <zen@xxxxxxxxxxxxxxx>wrote:
Hi,

paminy wrote (2008/03/09 23:29):

> First,thank you for your help. I have  run the HTS-demo_CMU-ARCTIC-SLT- Demo completely. Now I had another question about the Demo. 
> I want to see the .cmp files, I use the order : HList -C hlist.conf -h /hts/HTS-demo_CMU-ARCTIC-SLT2/data/cmp/cmu_us_arctic_slt_a0001.cmp>cmu_us_arctic_slt_a0001
> But I could not find hlist.conf.

If you're using little endian machines, please set hlist.conf as follows:

 NATURALREADORDER = TRUE

Otherwise, set as 

 NATURALREADORDER = TRUE

Regards,

Heiga ZEN (Byung Ha CHUN)

-- 
------------------------------------------------
 Heiga ZEN     (in Japanese pronunciation)
 Byung Ha CHUN (in Korean pronunciation)

 Department of Computer Science and Engineering
 Nagoya Institute of Technology
 Gokiso-cho, Showa-ku, Nagoya 466-8555 Japan

 http://www.sp.nitech.ac.jp/~zen
------------------------------------------------