[Subject Prev][Subject Next][Thread Prev][Thread Next][Date Index][Thread Index]

[hts-users:01340] Re: ERROR [+2121] HInit: Too Few Observation Sequences [0]


Zuko Fani wrote:
Hi

HTS can't pick up  segments because my labs are less than 5 frames where 1 frame length is 25ms. I tried reducing  FRAMELEN = 160 # Frame length in point (400 = 16000 * 0.01) from Makefile script. But still I'm receiving the same error ERROR [+2121]  HInit: Too Few Observation Sequences [0]. Is there another parameter I can change to accommodate my labels for phoneme boundaries.

That error message might actually mean that you have no examples of a particular segment type in your database.

Simon


--
The University of Edinburgh is a charitable body, registered in
Scotland, with registration number SC005336.


References
[hts-users:01339] ERROR [+2121] HInit: Too Few Observation Sequences [0], Zuko Fani