[Subject Prev][Subject Next][Thread Prev][Thread Next][Date Index][Thread Index]

[hts-users:01582] Re: GV causes clipping


Hello Nicholas,

I have had that problem when training with LSP parameters, but not with Mel-cepstrum
are you using any kind of LSP (lsp, Mel-lsp or Mgc-lsp)?

Regards,

Marcela.

Nicholas Volk wrote:
Hi all,

I'm applied global variance to a 22kHz male voice. There's some occasional
clipping when using gv. Without GV the results are fine. (Without gv the
min and max of the waveform are around +-20000, not far from SLT demo
voice.)
Have you had this clipping problem with any voices?

br,
  Nicholas




--
_______________________________________________________________
Marcela Charfuelan, Researcher, DFKI GmbH
Projektbuero Berlin, Alt-Moabit 91c, 10559 Berlin, Germany
Phone: +49 (0)30 39491821
URL  : http://www.dfki.de/~charfuel/
_______________________________________________________________
Deutsches Forschungszentrum fuer Kuenstliche Intelligenz GmbH
Firmensitz: Trippstadter Strasse 122, D-67663 Kaiserslautern
Geschaeftsfuehrung:
Prof. Dr. Dr. h.c. mult. Wolfgang Wahlster (Vorsitzender)
Dr. Walter Olthoff Vorsitzender des Aufsichtsrats:
Prof. Dr. h.c. Hans A. Aukes
Amtsgericht Kaiserslautern, HRB 2313
_______________________________________________________________


References
[hts-users:01578] GV causes clipping, Nicholas Volk