[hts-users:01762] HInit: Too Few Observation Sequences [0]
I'm trying to create a new voice using HTS 2.1. I've been able to run
tests on existing voices and that has worked well. I've set up my data
the way I think it needs to be set up. However, when I run "make
voice" I get an error. It says it doesn't have any instances of the
first phone "aa". My label files contain 942 instances of this phoneme
and they're all longer than 5 ms. The label format is converted to HTK
format. What could I be doing wrong?
Here is the error:
/usr/local/HTS-2.1/bin/HInit -A -C /Users/klabbers/Projects/HTS-
demo_OGI-AS/configs/t
rn.cnf -D -T 1 -S /Users/klabbers/Projects/HTS-demo_OGI-AS/data/scp/
train.scp -m 1 -u
tmvw -w 3 -H /Users/klabbers/Projects/HTS-demo_OGI-AS/models/qst001/
ver1/cmp/init.mm
f -M /Users/klabbers/Projects/HTS-demo_OGI-AS/models/qst001/ver1/cmp/
HInit -I /Users/
klabbers/Projects/HTS-demo_OGI-AS/data/labels/mono.mlf -l aa -o aa /
Users/klabbers/Pr
ojects/HTS-demo_OGI-AS/proto/ver1/state-5_stream-4_mgc-75_lf0-3.prt
HTK Configuration Parameters[9]
Module/Tool Parameter Value
# MINDUR 5
# MAXSTDDEVCOEF 10
# APPLYDURVARFLOOR TRUE
# DURVARFLOORPERCENTILE 1.000000
# VFLOORSCALESTR Vector 4 0.01 0.01 0.01 0.01
# MINLEAFOCC 0
# NATURALWRITEORDER TRUE
# NATURALREADORDER TRUE
# APPLYVFLOOR TRUE
Initialising HMM /Users/klabbers/Projects/HTS-demo_OGI-AS/proto/ver1/
state-5_stream-
4_mgc-75_lf0-3.prt . . .
States : 2 3 4 5 6 (width)
Mixes s1: 1 1 1 1 1 ( 75 )
( 75 )
Num Using: 0 0 0 0 0
Mixes s2: 2 2 2 2 2 ( 1 )
( MSD <= 1 )
Num Using: 0 0 0 0 0
Mixes s3: 2 2 2 2 2 ( 1 )
( MSD <= 1 )
Num Using: 0 0 0 0 0
Mixes s4: 2 2 2 2 2 ( 1 )
( MSD <= 1 )
Num Using: 0 0 0 0 0
Parm Kind: USER
Number of owners = 1
SegLab : aa
maxIter : 20
epsilon : 0.000100
minSeg : 1
Updating : Means Variances MixWeights/DProbs TransProbs
- system is PLAIN
ERROR [+2121] HInit: Too Few Observation Sequences [0]
FATAL ERROR - Terminating program /usr/local/HTS-2.1/bin/HInit
Error in /usr/local/HTS-2.1/bin/HInit -A -C /Users/klabbers/
Projects/HTS-demo_OGI
-AS/configs/trn.cnf -D -T 1 -S /Users/klabbers/Projects/HTS-demo_OGI-
AS/data/scp/trai
n.scp -m 1 -u tmvw -w 3 -H /Users/klabbers/Projects/
HTS-demo_OGI-AS
/models/qst001/ver1/cmp/init.mmf -M /Users/klabbers/Projects/HTS-
demo_OGI-AS/models/q
st001/ver1/cmp/HInit -I /Users/klabbers/Projects/HTS-demo_OGI-AS/data/
labels/mono.mlf
-l aa -o aa /Users/klabbers/Projects/HTS-demo_OGI-AS/proto/ver1/
state-5_stream-4_mgc
-75_lf0-3.prt
Esther Klabbers
Assistant Professor,
Center for Spoken Language Understanding (CSLU),
Division of Biomedical Computer Science (BMCS)
Oregon Health & Science University (OHSU)
20000 NW Walker Road / Beaverton, OR 97006
Office: +1-503-748-3005 / Fax: +1-503-748-1306
http://www.cslu.ogi.edu/people/klabbers
- Follow-Ups
-
- [hts-users:01763] Re: HInit: Too Few Observation Sequences [0], Nicholas Volk