Same problem occured in normal hts-demo when using data at 22khz, but
not so serious as in the straight hts.  When using data of 22khz, it
is a little more buzzy in normal hts with similar configuration as exp
2. Prof. Tokuda recommended mgc order 12~16 at 8khz, so i think a
higher mgc order should be used at 22khz in normal hts. But i am not
sure if a higher mgc order should be used in straight hts as in exp 2.

On 4/30/09, Keiichiro Oura <uratec@xxxxxxxxxxxxxxx> wrote:
> Hi,
>
> That's so strange.
> How about normal HTS-demo script with 22050Hz sampling data?
>
> Regards,
> Keiichiro Oura
>
> 康世胤 wrote:
>> The original date were sampled at 22050Hz. I used Sox to down-sample
>> the original data to 16kHz in the first experiment.  Recently I tried
>> to use the original data directly as shown in the second exp, and got
>> a very bad result.
>>
>> On 4/29/09, Keiichiro Oura <uratec@xxxxxxxxxxxxxxx> wrote:
>>> Hi,
>>>
>>> What hertz were original speech signals were sampled at?
>>> What tool did you use for down-sampling to 22050Hz?
>>> How about 32kHz?
>>>
>>> Regards,
>>> Keiichiro Oura
>>>
>>> 康世胤 wrote:
>>>> hi
>>>>
>>>> I have build a voice by straight hts at 16Khz using the following param
>>>> , and the voice is good.
>>>>
>>>> SAMPFREQ    = 16000
>>>> FRAMESHIFT  = 80
>>>> FREQWARP    = 0.42
>>>> GAMMA       = 0
>>>> MGCORDER    = 39
>>>> MGCLSP      = 0
>>>> LNGAIN      = 1
>>>>
>>>>
>>>>
>>>> Now I am trying to build a voice at 22khz.
>>>> The following parameters are applied when configure, but  I got a very
>>>> bad voice.
>>>>
>>>> SAMPFREQ    = 22050
>>>> FRAMESHIFT  = 110
>>>> FREQWARP    = 0.45
>>>> GAMMA       = 0
>>>> MGCORDER    = 39
>>>> MGCLSP      = 0
>>>> LNGAIN      = 1
>>>>
>>>>
>>>> Should I change some other param to meet the new sampling rate ?
>>>> I have searched the mail list,
>>>> and found that the mgc order should also be changed when using a
>>>> differen sampling rate in hts without straight.
>>>>
>>>> So, should it be changed in straight hts?
>>>> Is  there a recommended value at 22khz?
>>>> Is this value OK?
>>>>         mgcorder = 39 / 16k * 22k = 53
>>>>
>>>>
>>>>
>>>>
>>>> --
>>>> 康世胤
>>>> Shiyin Kang
>>>>
>>>
>>>
>>>
>>
>
>
>
>

-- 
Sent from Gmail for mobile | mobile.google.com

康世胤
Shiyin Kang

kangshiyin@xxxxxxxxx
Mobile: (+86)13810352340
Tel: (+8610)62775251

FIT 3-522
Lab of Human-Computer Speech Interaction,
Department of Computer Science & Technology,
Tsinghua University,Beijing, P.R.China, 100084

References
[hts-users:01958] How to configure HTS with STRAIGHT when using a different sampling rate?, 康世胤
[hts-users:01959] Re: How to configure HTS with STRAIGHT when using a different sampling rate?, Keiichiro Oura
[hts-users:01960] Re: How to configure HTS with STRAIGHT when using a different sampling rate?, 康世胤
[hts-users:01961] Re: How to configure HTS with STRAIGHT when using a different sampling rate?, Keiichiro Oura