- Dkim-signature: v=1; a=rsa-sha256; c=relaxed/relaxed; d=gmail.com; s=gamma; h=domainkey-signature:mime-version:received:in-reply-to:references :date:message-id:subject:from:to:content-type :content-transfer-encoding; bh=e9DnGZXGJCrYazJFHhdSy605KfoOi5B10Kni5aavt/Y=; b=k+51mu+Za1tpTVUW8MD71p/rly4uVU2ngOa2QQHiVENEFbPuhPbIFVDSioPGLdKAUK Jzz0tNIavtbA2wQA+ndlJPziBrv6m4rWtI6pNGNNQTTS6U6ePMEwqQsrpYTPXYbocvzg coYDuNJEilpD+ToDZwPd9oRjnUT3+NKEzz3sQ=
- Domainkey-signature: a=rsa-sha1; c=nofws; d=gmail.com; s=gamma; h=mime-version:in-reply-to:references:date:message-id:subject:from:to :content-type:content-transfer-encoding; b=q7abD2BwC/b/XagfPU2pSkzXdjvtLP83yh6sTWnMdkFnsqO3/9MR3P0p2q2p/KYQsN svRkmX0HgElOO4eI8Gk1pweLFPLufkxP9DWH8KrJ5y/w6cffIvQ6fVxAffRfyOXzL4kC idQV0N4iVAeJUARD5NJ57UH9B0aOJVSL0Zlps=
Same problem occured in normal hts-demo when using data at 22khz, but
not so serious as in the straight hts. When using data of 22khz, it
is a little more buzzy in normal hts with similar configuration as exp
2. Prof. Tokuda recommended mgc order 12~16 at 8khz, so i think a
higher mgc order should be used at 22khz in normal hts. But i am not
sure if a higher mgc order should be used in straight hts as in exp 2.
On 4/30/09, Keiichiro Oura <uratec@xxxxxxxxxxxxxxx> wrote:
> Hi,
>
> That's so strange.
> How about normal HTS-demo script with 22050Hz sampling data?
>
> Regards,
> Keiichiro Oura
>
> 康世胤 wrote:
>> The original date were sampled at 22050Hz. I used Sox to down-sample
>> the original data to 16kHz in the first experiment. Recently I tried
>> to use the original data directly as shown in the second exp, and got
>> a very bad result.
>>
>> On 4/29/09, Keiichiro Oura <uratec@xxxxxxxxxxxxxxx> wrote:
>>> Hi,
>>>
>>> What hertz were original speech signals were sampled at?
>>> What tool did you use for down-sampling to 22050Hz?
>>> How about 32kHz?
>>>
>>> Regards,
>>> Keiichiro Oura
>>>
>>> 康世胤 wrote:
>>>> hi
>>>>
>>>> I have build a voice by straight hts at 16Khz using the following param
>>>> , and the voice is good.
>>>>
>>>> SAMPFREQ = 16000
>>>> FRAMESHIFT = 80
>>>> FREQWARP = 0.42
>>>> GAMMA = 0
>>>> MGCORDER = 39
>>>> MGCLSP = 0
>>>> LNGAIN = 1
>>>>
>>>>
>>>>
>>>> Now I am trying to build a voice at 22khz.
>>>> The following parameters are applied when configure, but I got a very
>>>> bad voice.
>>>>
>>>> SAMPFREQ = 22050
>>>> FRAMESHIFT = 110
>>>> FREQWARP = 0.45
>>>> GAMMA = 0
>>>> MGCORDER = 39
>>>> MGCLSP = 0
>>>> LNGAIN = 1
>>>>
>>>>
>>>> Should I change some other param to meet the new sampling rate ?
>>>> I have searched the mail list,
>>>> and found that the mgc order should also be changed when using a
>>>> differen sampling rate in hts without straight.
>>>>
>>>> So, should it be changed in straight hts?
>>>> Is there a recommended value at 22khz?
>>>> Is this value OK?
>>>> mgcorder = 39 / 16k * 22k = 53
>>>>
>>>>
>>>>
>>>>
>>>> --
>>>> 康世胤
>>>> Shiyin Kang
>>>>
>>>
>>>
>>>
>>
>
>
>
>
--
Sent from Gmail for mobile | mobile.google.com
康世胤
Shiyin Kang
kangshiyin@xxxxxxxxx
Mobile: (+86)13810352340
Tel: (+8610)62775251
FIT 3-522
Lab of Human-Computer Speech Interaction,
Department of Computer Science & Technology,
Tsinghua University,Beijing, P.R.China, 100084
- References
-
- [hts-users:01958] How to configure HTS with STRAIGHT when using a different sampling rate?, 康世胤
- [hts-users:01959] Re: How to configure HTS with STRAIGHT when using a different sampling rate?, Keiichiro Oura
- [hts-users:01960] Re: How to configure HTS with STRAIGHT when using a different sampling rate?, 康世胤
- [hts-users:01961] Re: How to configure HTS with STRAIGHT when using a different sampling rate?, Keiichiro Oura