[hts-users:02034] Re: Problem Feature Extraction
- Subject: [hts-users:02034] Re: Problem Feature Extraction
- From: Geoffrey Wilfart <geoffrey.wilfart@xxxxxxxxx>
- Date: Mon, 22 Jun 2009 09:51:26 +0200
- Delivered-to: hts-users@xxxxxxxxxxxxxxx
- Dkim-signature: v=1; a=rsa-sha256; c=relaxed/relaxed; d=gmail.com; s=gamma; h=domainkey-signature:mime-version:received:in-reply-to:references :date:message-id:subject:from:to:content-type; bh=N4cygHJjWhtJLfF9CfS7mdDoDDMrEXzw+9OPET0KRgU=; b=haz4LB7GiTNrj9nueSwMwGAdT4EbeIRoKJkbuI7fpkl8jItrGGxKqwp+1VBQ2iqY1/ ZsBIYpVp5qEMG7bSK35JKh28h6HN8RB5E0HI6KtmHzURODzF5Z1f7askSrWgnq20R/q8 VQeAsQqOlw+beMycshmxlNg5Utcd1j/G0p+Jc=
- Domainkey-signature: a=rsa-sha1; c=nofws; d=gmail.com; s=gamma; h=mime-version:in-reply-to:references:date:message-id:subject:from:to :content-type; b=whz2ReEg+7uvFUT5ixAvQpuFdbLYAW6cIa3GaUj+Dkf223yh9Hf/h2dfltRRuL586B oLCE/v88LZgTuk73xTJf/7VBzlljio2NI72GQAalTTS8tKAY1w9pGR1mwEZ60Aafd8wp bf25/eo8r7PqfouQOhb2yMrWe4KXgvgqaprbQ=
Hi,
It will be harmful, since the feature extraction stops when the error raises. This means that you have incomplete features (and later cmp) files.
You might then get not enough or no data for some units.
Regards,
Geoffrey
2009/6/22 wangxiang
<wangxiang68@xxxxxxxxx>
MGCORDER=12 MGCLSP=1 GAMMA=3 FREQWARP=0.42 LNGAIN=1
>
While extracting using mgc-lsp
> Extracting MGC-LSP coefficients from raw/cmu_us_arctic_slt_a0289.raw
> mgcep : Error in theq() at 0th iteration!
> Extracting MGC-LSP coefficients from raw/cmu_us_arctic_slt_a0290.raw
> Extracting MGC-LSP coefficients from raw/cmu_us_arctic_slt_a0291.raw
> Extracting MGC-LSP coefficients from raw/cmu_us_arctic_slt_a0292.raw
> mgcep : Error in theq() at 0th iteration!
> Extracting MGC-LSP coefficients from raw/cmu_us_arctic_slt_a0293.raw
> Extracting MGC-LSP coefficients from raw/cmu_us_arctic_slt_a0294.raw
>
> Does anybody tell me what happened? Is there any harmful for following
> training?
It
means that determinant of Toeplitz+Hankel matrix, which is a
coefficient matrix of a linear system in MGC analysis, is too small
(<
1.0e-6).
You can modify this threshold via -f option as a smaller threshold
Does anyone know the reason for this warning and Is it harmful to the model training?
Thanks!
--
Xiang Wang
- Follow-Ups
-
- [hts-users:02035] Re: Problem Feature Extraction, wangxiang
- References
-
- [hts-users:02033] Problem Feature Extraction, wangxiang