- Dkim-signature: v=1; a=rsa-sha256; c=relaxed/relaxed; d=gmail.com; s=gamma; h=mime-version:date:message-id:subject:from:to:content-type; bh=ZguWX0ANAuUx4igOlNeL2pczXHwexqbWWbo3Na8r0kM=; b=wPrGDOhkSy6aqbXs7y2l3OxiSxieDUUD8652Y4eVpIXFwipmXqJ2mhld0zkCBJoz9t YCQKLQ1yIxZl+TPp2o8p0sRkDk0jespoB1uXIVjEYxLak1478OTOvi0O36xXFIGtWxJD Cjwkw16DcxUT+1gx5Y6V12/t9SPm1xXMQJkyI=
hi.
I have used hts-2.2ver.
When using a mlsa filter(pulse or noise),
if postfilter coef.(beta) value is 0.4 or higher, synthesis speech is divergence.
The parameters I use are as follows:
mgc order : 50
sampling frequency : 48000Hz
Is the range of beta 0~0.8 ?
When I used hts-2,1ver, there was no such problem. (mgc order:25, sampling frequency:16000Hz)
This issue is related to the mgc order? or samling frequency ?