[Subject Prev][Subject Next][Thread Prev][Thread Next][Date Index][Thread Index]

[hts-users:03413] Re: x2x : warning: input data is over the range of type 'short'!


It could be:
a. The volume of parts of your training data exceeds the quantitative limit;
b. You are using MGC-LSP.

--
Xingyu Na (那兴宇)
Beijing Institute of Technology

At 2012-09-28 18:22:08,"Veera Raghavendra" <raghavendra@xxxxxxxxxx> wrote:
Hi,

I have build HTS voice using HTS 2.2 version using 48KHz files. Following is the description of the data.

1. Number of sentences: 1000
2. Language: English
3. Length of the sentence: 5 to 20 words
4. Sampling frequency: 48KHz

Models are smoothly built and synthesis was done on the test sentences. But, during synthesis following error is thrown

x2x : warning: input data is over the range of type 'short'!

Spectrogram is showing dark frequency range from 0 to 24KHz (attached image shows the same). 

Please let me know any mistake that might have done by me in the setup or any changes for the better quality.

Thanks,
Raghavendra.

Follow-Ups
[hts-users:03414] Re: x2x : warning: input data is over the range of type 'short'!, Veera Raghavendra
References