[Subject Prev][Subject Next][Thread Prev][Thread Next][Date Index][Thread Index]

[hts-users:01341] Re: ERROR [+2121] HInit: Too Few Observation Sequences [0]


Hi

There are more than 115 examples of the phoneme in the dataset. 

regards
Zuko



>>> Simon King <Simon.King@xxxxxxxx> 04/17/08 4:39 PM >>>
Zuko Fani wrote:
> Hi
>
> HTS can't pick up  segments because my labs are less than 5 frames where 1 frame length is 25ms. I tried reducing  FRAMELEN = 160 # Frame length in point (400 = 16000 * 0.01) from Makefile script. But still I'm receiving the same error ERROR [+2121]  HInit: Too Few Observation Sequences [0]. Is there another parameter I can change to accommodate my labels for phoneme boundaries.

That error message might actually mean that you have no examples of a 
particular segment type in your database.

Simon


-- 
The University of Edinburgh is a charitable body, registered in
Scotland, with registration number SC005336.




-- 
This message is subject to the CSIR's copyright terms and conditions, e-mail legal notice, and implemented Open Document Format (ODF) standard. 
The full disclaimer details can be found at http://www.csir.co.za/disclaimer.html.

This message has been scanned for viruses and dangerous content by MailScanner, 
and is believed to be clean.  MailScanner thanks Transtec Computers for their support.


Follow-Ups
[hts-users:01342] Re: ERROR [+2121] HInit: Too FewObservation Sequences [0], 孙敬伟